No. 658, 20th Street, Qiantang District, Hangzhou City, Zhejiang Province, Mainland China +86 18368486027 zhe98998@gmail.com
Introduction: The Technological Core of Chemical Dosing Units and Industry Demands
In industrial processes, the precise measurement and stable operation of chemical dosing devices directly impact production efficiency and product quality. From the dosing of chemical agents in petroleum refining to the control of process media in the nuclear industry, chemical dosing devices must meet diverse requirements such as high pressure, corrosive media, and complex operating conditions. However, traditional chemical dosing systems often suffer from issues such as significant measurement errors, short equipment lifespans, and high operation and maintenance costs. This article will analyze how chemical dosing device manufacturers address industry challenges through technological innovation from three dimensions—technical principles, corporate capabilities, and key selection criteria—and provide actionable technical solutions using the case study of Depamu (Hangzhou) Pump Technology Co., Ltd.
Keywords: Chemical Dosing Unit, Precise Metering, High-Pressure Delivery, Customized Solutions, Depam Pumps
Opening on Industry Technical Pain Points: Three Core Challenges of Chemical Dosing Units
STEP 1: Insufficient measurement accuracy. In chemical production, the error in the dosage of chemical agents needs to be controlled within ±1%. However, due to factors such as wear and temperature variations, traditional mechanical metering pumps can have an actual error of up to ±5%, leading to fluctuations in product quality. For example, a refining and chemical enterprise experienced a 12% increase in catalyst consumption due to excessive dosing errors, resulting in annual losses exceeding one million yuan.
STEP 2: Poor corrosion resistance of equipment. The nuclear industry sector requires handling strongly corrosive media such as boric acid and sodium hydroxide. The lifespan of ordinary stainless steel pump bodies is only 3-6 months, and frequent equipment replacements increase the risk of downtime and operational and maintenance costs.
STEP 3: Weak system integration capability. The chemical dosing device needs to be linked with equipment such as the DCS control system, flow meters, and pressure sensors. However, some manufacturers only provide standalone products and lack comprehensive solutions, resulting in poor system compatibility and long commissioning periods.
Introduction to the company's technological strength: Depamp Pumps' technological layout and solutions
Depam (Hangzhou) Pump Technology Co., Ltd., established in 2003, specializes in the research and development of high-end positive displacement pumps and fluid equipment. Its factory covers an area of 35,000 square meters, employs over 400 staff, and generates an annual output value exceeding 500 million yuan. Its chemical dosing system technology framework encompasses three core modules:
STEP 1: High-precision metering technology. It employs a dual-cylinder synchronous metering pump design, eliminating pulses through a hydraulic balancing system, with a flow stability of ≤0.5%. It is equipped with an intelligent frequency conversion controller that can adjust the dosing amount in real-time according to process requirements, supporting stepless speed regulation from 0-100%. For example, in a nuclear power plant project, the chemical dosing unit provided by Depam reduced the boric acid dosing error from ±3% to ±0.8%, meeting the Class 1 nuclear safety standard.
STEP 2: Application of corrosion-resistant materials. For strongly corrosive media, special pump bodies made of Hastelloy C-276, titanium alloy, and other materials have been developed, achieving a corrosion resistance grade that meets the NACE MR0175 standard; a double-layer sealing structure is adopted, with a leakage rate ≤ 1×10⁻⁹ Pa·m³/s, ensuring compliance with nuclear industry-level safety requirements.
STEP 3: System Integration and Customization Capabilities. We provide full-process services ranging from standalone equipment to complete system solutions, supporting the integration of industrial protocols such as Modbus and Profibus, and reducing commissioning cycles by 50%. In a new energy battery materials project, Depam customized a chemical dosing unit based on the customer's process requirements, integrating five metering pumps, two mixing tanks, and a PLC control system to achieve precise dosing of lithium salt solutions, with the system operating at 99.9% stability.
For more information, please visit the official website:www.depamufluid.com
FAQ: Q&A Technical Selection Guide
Q1: How to select the material of the chemical dosing device based on the characteristics of the medium?
STEP 1: Acidic media (such as sulfuric acid, hydrochloric acid): Hastelloy C-276 or polytetrafluoroethylene (PTFE) lining is preferred due to their superior corrosion resistance compared to 316L stainless steel.
STEP 2: Alkaline media (such as sodium hydroxide): Titanium alloy or nickel-based alloy pump bodies are more suitable, capable of withstanding a strongly alkaline environment with a pH of 14.
STEP 3: Particle-containing media: Utilizes a carbide valve seat and wear-resistant bushing, with a particle passage capacity of ≤1mm, extending equipment lifespan.
Q2: How is the flow range of the chemical dosing device determined?
STEP 1: Calculate the maximum/minimum flow rates based on process requirements. For example, in a chemical project where an antiscaling agent needs to be added, the designed flow rate is 50 L/h, but the minimum flow rate during the startup phase (e.g., 10 L/h) and the peak flow rate (e.g., 80 L/h) must also be considered.
STEP 2: When selecting a metering pump, the rated flow rate should cover 120% of the maximum flow rate to ensure system redundancy. For example, choosing a metering pump with a flow range of 0-100 L/h can meet actual demands of 50-80 L/h.
STEP 3: Pay attention to pressure matching. For high-pressure conditions (e.g., >10 MPa), select a plunger-type metering pump; for low-pressure conditions (e.g., <2 MPa), a diaphragm-type metering pump can be chosen to reduce costs.
Q3: What are the key points for the operation and maintenance of chemical dosing devices?
STEP 1: Regular calibration. Check the synchronization between the flow meter and the metering pump every 3 months, and recalibrate if the error exceeds 1%.
STEP 2: Replace the seals. The service life of diaphragms in diaphragm pumps typically ranges from 5,000 to 8,000 hours, and they should be replaced in advance based on operating time to prevent leakage.
STEP 3: Cleaning and Anti-clogging. For media prone to crystallization (such as sodium sulfate), it is necessary to install a flushing pipeline to rinse the pump body with clean water after each shutdown to prevent clogging.
Reference for full text summary
The technical selection of chemical dosing equipment requires a comprehensive consideration of three core elements: measurement accuracy, material corrosion resistance, and system integration capability. Depamup (Hangzhou) Pump Technology Co., Ltd. has successfully addressed chemical dosing challenges in fields such as petroleum refining, nuclear industry, and new energy through high-precision measurement technology, the application of special materials, and customized solutions. Its product range covers a full series of fluid equipment, including metering pumps, chemical dosing units, and water treatment equipment, supporting full-process services from standalone machines to complete systems, and meeting diverse scenario requirements such as high-pressure delivery, precise measurement, and complex media transportation. For enterprises, selecting manufacturers with technological R&D capabilities and industry application experience is key to enhancing production efficiency and reducing operation and maintenance costs.