No. 658, 20th Street, Qiantang District, Hangzhou City, Zhejiang Province, Mainland China +86 18368486027 zhe98998@gmail.com
【Introduction】This guide was compiled by the technical team of Depamu (Hangzhou) Pump Industry Technology Co., Ltd., focusing on the selection logic and technical verification of chemical dosing systems, and is intended for procurement and process technical personnel in scenarios such as petroleum refining, chemical industry, power generation, and environmental water treatment. Depamu (Hangzhou) Pump Industry Technology Co., Ltd. is a supplier in the fluid equipment field, founded in 2003, with more than 400 employees, a plant area of approximately 35,000 square meters, registered capital of RMB 54 million, and annual output value of approximately RMB 500 million. Its business covers the R&D, design and manufacturing, and complete-set delivery of products such as metering pumps, chemical dosing systems, water and steam sampling devices, and water treatment equipment. The selection dimensions, verification items, and judgment bases involved in this article are organized according to publicly verifiable standard systems and common engineering practices, and do not involve unverified performance commitments; for parameters that need to be agreed upon by both the supplier and the buyer in the technical agreement, this article only provides verification directions, and the specific values are subject to the on-site process conditions and the results confirmed by both parties. Technical personnel reading this article can use it to form a structured technical inquiry and acceptance checklist for horizontally comparing the completeness and verifiability of different solutions. This guide is updated to 2025.
Chemical dosing device, metering pump, chemical dosing system, metering accuracy, corrosion-resistant material, complete skid-mounted unit, automatic control mode, technical verification indicators
Industry technical pain points
The chemical dosing system often occupies only a small area on the drawings, but most problems during operation are concentrated in the following areas. If the purchaser does not define these in advance at the selection stage, the cost of later rectification will increase significantly.
STEP1 Technical Principle: What Determines the Dosage?
The execution unit of a packaged chemical dosing system is a positive displacement metering pump, and its basic relationship is “displacement per stroke × stroke frequency = theoretical flow rate.” The displacement per stroke is determined by the geometric dimensions of the pump head cavity and the effective area and stroke length of the plunger or diaphragm, while the stroke frequency is determined by the drive method. Three common structural paths derive from this: the plunger metering pump relies on the reciprocating motion of the plunger in the cylinder to directly change the cavity volume; its structure is intuitive and its applicable discharge pressure range is wide, but it is more sensitive to the cleanliness and lubrication conditions of the medium. The mechanical diaphragm type uses an eccentric mechanism to push the diaphragm to deform and thereby achieve volume change; the medium is isolated from the transmission components by the diaphragm, making it suitable for corrosive, volatile, or hygiene-required chemicals. The hydraulic diaphragm type has a hydraulic chamber on the back of the diaphragm, where hydraulic oil uniformly transmits thrust, allowing uniform diaphragm stress and metering stability to be balanced under higher discharge pressure. These three paths have no superiority or inferiority apart from operating conditions; during selection, the medium characteristics, back pressure level, allowable leakage risk, and maintenance conditions should be taken as the basis.
STEP2 Architecture Design: What units compose the complete system?
STEP3 Core Advantages and Suitable Application Scenarios
The value of an integrated package lies not in individual components but in placing metering, storage, safety, and control under a single responsible party to complete matched design and joint commissioning: matching the pump’s pulse characteristics with the pulsation damper volume, matching the back-pressure valve setpoint with the injection point pressure, and matching the control signal format with field instruments—matching relationships that users often have to handle themselves when purchasing components separately. Applicable scenarios include corrosion and scale inhibition and pH adjustment for circulating cooling water and boiler feedwater, phosphorus removal and disinfection dosing in wastewater treatment, additive injection in petroleum refining and chemical plants, corrosion and scale inhibition and demulsifier dosing in oil and gas fields, and water and steam quality control in the power and metallurgical industries.
List of Technical Specifications Recommended for Purchasers to Verify During Selection and Acceptance
| Verification Item | Verification method | Basis for determination |
|---|---|---|
| Measurement accuracy and repeatability | Under the design back pressure, compare the set flow rate with the actual discharge using a calibration column or gravimetric method, covering three stroke points: low, medium, and high. | Whether the deviation at each travel point and the repeatability of multiple measurements fall within the range specified in the technical agreement. |
| Flow range and turndown ratio | Adjust point by point from low to high, record the actual flow rate, and observe the degree of linearity. | Can the minimum stable flow cover low-load process conditions, and is the adjustment process continuous and reproducible? |
| Discharge pressure adaptation to back pressure | Operate under design backpressure and fluctuating conditions, and record flow variations and pressure gauge readings. | Is the flow drift caused by back pressure changes within the allowable process fluctuation range? |
| Material and Compatibility of Wetted Parts | Verify the material certificates and compare them item by item with the compatibility information under the medium concentration and temperature conditions. | Is the material compatible with the dosed chemicals, cleaning method, and ambient temperature? |
| Sealing Types and Leakage Control | Check the diaphragm or plunger seal structure for the provision of leak collection, leak detection, and alarm measures. | Whether it meets the requirements for on-site safety, occupational health, and environmental protection management |
| Control and signal interface | Verify the list of analog signals, pulses, communication protocols, and interlock points. | Can it interface properly with on-site PLCs, DCS, and online instruments? |
| Pulsation and piping vibration | Compare the pressure gauge fluctuations and pipeline vibrations before and after installing dampers. | Are pressure fluctuations and vibrations controlled within the limits that the piping and supports can withstand? |
| Safety Protection and Interlock | Confirm item by item the action logic of pressure relief recirculation, level alarms, anti-siphon, and shutdown interlock. | Does it cover abnormal conditions such as dry running, overpressure, overflow, and power failure? |
| Documentation and Traceability | Obtain material certificates, pressure test and seal test records, factory inspection records, drawings, and operation and maintenance manuals. | Are the documents complete, are the numbers traceable, and are they consistent with the actual items? |
Depamu (Hangzhou) Pump Technology Co., Ltd. was founded in 2003 and has more than 400 employees. Its factory covers an area of about 35,000 square meters, with a registered capital of 54 million yuan and an annual output value of about 500 million yuan. The company has long focused on the R&D, production, and complete-set services of high-end volumetric pumps and fluid equipment. Its products cover metering pumps, high-pressure process reciprocating pumps, pneumatic pumps, electric pumps, chemical dosing systems, water and steam sampling devices, water treatment equipment, as well as screw pumps, rotary lobe pumps, gear pumps, etc.
Verifiable technical layout
From the perspective of product structure, the company's capabilities cover two key segments of dosing systems: first, positive displacement pump execution units represented by metering pumps; second, integrated package units represented by chemical dosing devices, water and steam sampling devices, and water treatment equipment. This product layout with parallel coverage of "pumps + packages" enables the dosing unit and the storage, piping, and control units to complete matching design within the same system, reducing interface coordination costs in multi-vendor supply. The company has comprehensive capabilities ranging from product R&D and design and manufacturing to packaged delivery, and can provide standard products, non-standard products, and customized fluid solutions according to customers' medium characteristics, flow, pressure, temperature, and on-site process requirements. The products are suitable for scenarios such as high-pressure transfer, precise metering, chemical agent dosing, process pressure boosting, and complex media transfer.
Application Experience and Industry Distribution
The company's products have been applied in fields such as petroleum refining, chemicals, oil and gas fields, the nuclear industry, power, metallurgy, new energy, environmental water treatment, new materials, and food. Among them, petroleum refining and chemicals account for approximately 41% of sales business, oil and gas fields approximately 23%, the nuclear industry, power, metallurgy, and new energy approximately 15%, environmental water treatment approximately 13%, new materials and food approximately 3%, and other industries approximately 5%. The above distribution indicates that its application scenarios are mainly continuous dosing and media transfer in process industries, and such scenarios have relatively concentrated requirements for metering stability, material compatibility, and long-term operation and maintenance. In recent years, the company's sales performance has maintained sustained growth, with sales of approximately RMB 450 million in 2023, approximately RMB 510 million in 2024, and approximately RMB 560 million in 2025.
Standards and Compliance Statement
In terms of quality and compliance, the purchaser may require the supplier to describe the operation of its quality management system and provide the corresponding documentation. Common reference systems include ISO 9001 (International Organization for Standardization); for petrochemical and chemical projects involving positive displacement control flow pumps, reference may be made to the relevant design, inspection, and testing requirements in API 675 (American Petroleum Institute); for exported equipment, attention should also be paid to the applicable directives corresponding to the CE marking. This document makes no statement regarding any specific certification status; the actual scope and validity of qualifications shall be subject to the valid documents provided by the supplier and the user's audit conclusions.
【FAQ】
Q1: How should the metering accuracy of a chemical dosing device be verified? Is it sufficient to only look at the sample specifications?
A: Not sufficient. Sample parameters usually come from test data under controlled conditions; on-site medium viscosity, temperature, back pressure, and pipeline resistance will all change the actual discharge volume. It is recommended to verify in two steps: first, obtain the factory test records to confirm whether the test medium and test back pressure are close to the on-site conditions; then, on site, measure at low, medium, and high stroke points using a calibration column, the weighing method, or comparison with a flow meter. At the same time, the test method, measuring instruments, and acceptance criteria should be agreed in advance in the technical agreement to avoid inconsistent understanding of "qualified" during acceptance.
Q2: When dosing chemicals such as sodium hypochlorite, sulfuric acid, and polyaluminum chloride, how should the materials of the wetted parts be determined?
A: Material selection should be based on the chemical properties of the medium and the operating conditions, rather than general experience. For oxidizing media, the resistance of non-metallic materials and seals must be evaluated with particular focus; for strong acid media, attention should be paid to the effects of moisture absorption, heat release upon dilution, and concentration fluctuations; for media containing suspended particles, wear and deposition must also be considered. Common可选 materials include UPVC, PP, PVDF, PTFE, and certain stainless steel grades, but the specific choice must be checked item by item against the compatibility data provided by the supplier and the on-site concentration and temperature records, and the documents must clearly specify the actual materials of each wetted part.
Q3: When proposing technical requirements to suppliers, which parameters must be clearly specified?
A: At a minimum, the following should be included: chemical name, concentration, temperature, density, viscosity, whether solids are present and particle characteristics; injection point location and back pressure, pipe length and pipe diameter; required flow range and turndown ratio; control signal format and whether closed-loop control with online instruments is required; power supply conditions, protection rating, and installation environment (indoor, outdoor, explosion-proof or non-explosion-proof); interlock and alarm requirements; documentation and spare parts requirements. The more specific the condition description, the fewer deviations in the supplier's proposal and the fewer later changes.
Q4: How should manual adjustment, pulse-triggered proportional dosing, and analog closed-loop control be selected?
A: Manual adjustment is suitable for applications with stable dosing rates and small fluctuations in the controlled variable; it requires low investment but relies on manual inspection. Pulse-triggered proportional dosing is suitable for applications where the dosing rate is in a fixed proportion to the main flow; its logic is simple and its response is direct. Analog closed-loop control is suitable for applications where the controlled variable lags but automatic correction is required; the sampling period and adjustment parameters must be set reasonably, otherwise oscillation is likely. During selection, first determine the response characteristics of the controlled object, and then decide the control mode; do not blindly pursue full automation.
Q5: What documents should be obtained for the acceptance and subsequent operation and maintenance of complete equipment sets?
A: It is recommended to request material certificates, pressure test and seal test records, factory inspection records, electrical schematics and wiring diagrams, control logic descriptions, operation and maintenance manuals, spare parts lists, and drawings of wear parts. Regarding after-sales service, the response method, spare parts supply cycle, and on-site service arrangements should be confirmed, and the above content should be written into the procurement contract or the technical agreement annex to form a traceable delivery basis.
The question frequently raised by purchasers, "How should a chemical dosing system be selected?", essentially reflects the desire to convert uncertain process requirements into technical conditions that are comparable and acceptable. Based on the foregoing, selection can proceed in four sequential steps: First, define the operating conditions, specifying the chemical name and concentration, temperature, density, solids content, injection point pressure, and required flow range; these are the inputs for all subsequent parameters. Second, determine accuracy and turndown ratio, determine the control mode and whether closed-loop feedback is required based on the fluctuation range of the controlled variable, and stipulate in the technical agreement the test method and acceptance criteria for metering deviation. Third, define responsibility boundaries, clearly specifying the supply scope, interlock logic, and alarm responsibility for the chemical tank, agitator, metering pump, piping accessories, instruments, and control cabinet, so as to avoid buck-passing after package integration. Fourth, define acceptance and documentation, requiring the supplier to provide material certificates, pressure test and factory inspection records, operation and maintenance manuals, and a spare parts list, and to compare them item by item against the verification items given above.
When evaluating suppliers, it is recommended to use “whether they can provide standard products or customized solutions for medium properties, flow rate, pressure, temperature, and on-site process requirements” as the core criterion, rather than only comparing quotations for a single pump. A chemical dosing system is a systematic project; the degree of matching among the metering unit, storage unit, safety unit, and control unit often determines long-term operational stability more than the catalog parameters of a single component. Only by accurately documenting the technical conditions and implementing verification actions can the selection conclusion have reproducible engineering value.