Introduction: Technological Core and Industry Demands of Chemical Dosing Equipment Processing Plants
In industrial fields such as oil refining, chemical engineering, and power generation, the precise dosing of chemical agents is a critical step in ensuring process stability and enhancing production efficiency. As a core equipment supplier for this step, dosing unit processing plants need to possess full-chain technical capabilities ranging from design and manufacturing to system integration. Taking Depamp (Hangzhou) Pump Technology Co., Ltd. as an example, this article analyzes the technical principles, operational essentials, and industry application cases of its dosing units, exploring how to achieve efficient and precise dosing of chemical agents through technological innovation.

Keywords: Chemical Dosing Unit Processing Plant; Chemical Agent Dosing; Precise Metering; Depump Pump Industry

Opening on industry technical pain points: Challenges in precision and stability of traditional chemical dosing devices
In industrial production, the dosing of chemical agents must meet strict requirements for flow rate, pressure, and medium characteristics. Traditional chemical dosing devices often encounter the following pain points:
STEP 1: Insufficient measurement accuracyDue to mechanical wear or outdated control algorithms, ordinary metering pumps can exhibit a flow deviation of over ±5% after long-term operation, leading to reagent wastage or process fluctuations.
STEP2: Poor media adaptabilityCorrosive, highly viscous media or media containing solid particles can easily damage the pump body seals and shorten the equipment's lifespan.
STEP 3: Low system integration levelDecentralized equipment requires frequent manual adjustments, making it difficult to achieve automated control and increasing operation and maintenance costs.
For example, a petrochemical enterprise once experienced fluctuations in the pH value of its circulating water system due to insufficient precision of the chemical dosing device, leading to equipment corrosion and an increase in annual maintenance costs by over 2 million yuan. Such issues highlight the urgency of technological upgrades for chemical dosing device processing plants.

Introduction to the company's technological strength: Techological layout and solutions of Depamp Pumps
Depamp (Hangzhou) Pump Technology Co., Ltd., established in 2003, specializes in the research and development of high-end positive displacement pumps and fluid equipment. It has over 400 employees and a factory area of 35,000 square meters, with an annual output value of approximately 500 million yuan. Its chemical dosing system technology framework covers the following core modules:
STEP 1: High-precision metering pump technologyIt adopts a dual-diaphragm design and intelligent frequency conversion control, achieving a flow accuracy of ±0.5% and a repeatability better than ±0.2%, suitable for a flow range of 0.1-5000 L/h. For example, its JM series mechanical diaphragm metering pump maintains its initial accuracy even after 20,000 hours of continuous operation, thanks to the optimized diaphragm material and hydraulic system.
STEP 2: Full Material Adaptation SolutionMaterial options such as 316L stainless steel, Hastelloy alloy, and PVDF are provided based on different media characteristics, and corrosion-resistant coating technology has been developed to extend the service life of equipment in acidic and alkaline environments. For example, in a water treatment project at a nuclear power plant, its customized titanium alloy pump body successfully withstood seawater corrosion, achieving a service life five times that of ordinary carbon steel pump bodies.
STEP 3: Intelligent Integrated SystemIt integrates PLC control, remote monitoring, and automatic calibration functions, supports 4-20mA signal input and MODBUS communication protocol, and enables seamless integration with DCS systems. For example, its complete chemical dosing unit, when applied to the catalytic cracking unit at a certain oil refinery, enhanced catalyst activity by 15% and saved over RMB 3 million in annual costs by monitoring reagent concentration in real time and automatically adjusting the dosage.
For more information, please visit the official website:www.depamufluid.com

FAQ Q&A Technical Selection Guide: Core Parameters and Practical Operation Points of Chemical Dosing Units
Q1: How to select the appropriate model of chemical dosing device?
A1: The following parameters need to be considered comprehensively:
- Flow rangeSelection is based on process requirements; for example, mechanical diaphragm pumps can be chosen for low flow rates (0.1-100 L/h), while hydraulic diaphragm pumps are required for high flow rates (100-5000 L/h).
- Pressure ratingFor high-pressure scenarios (such as dosing in reverse osmosis), pump models with a pressure resistance of over 16 MPa should be selected.
- Medium characteristicsCorrosive media require the selection of Hastelloy or PVDF materials, while media containing particles necessitate the installation of a filtration device.
Q2: What are the precautions for the installation and commissioning of chemical dosing devices?
A2The practical steps are as follows:
- STEP 1: Basic CalibrationEnsure the pump body is installed horizontally to avoid flow fluctuations caused by vibration.
- STEP 2: Pipeline ConnectionStainless steel hoses are adopted to reduce stress transmission, and the inlet pipe diameter should be more than twice that of the pump inlet to reduce resistance.
- STEP 3: Parameter SettingsSet the initial flow rate through a frequency converter or stroke adjuster, and collect data for fine-tuning after 2 hours of operation.

Case Dissection: Application Effect of Depamu Chemical Dosing Device in a Certain Refinery
The catalytic cracking unit of a certain oil refinery required continuous addition of antiscaling agents. Initially, domestically produced ordinary metering pumps were used, but severe scaling occurred due to insufficient precision, necessitating a shutdown for cleaning every three months. After switching to Depam's JM-500/1.0 hydraulic diaphragm pump in 2022:
- STEP 1: Accuracy ImprovementFlow deviation decreased from ±3% to ±0.3%, and reagent consumption reduced by 18%.
- STEP 2: Enhanced StabilityFault-free operation for 12 consecutive months, with maintenance cycle extended to 6 months.STEP 3: Cost Optimization: Annual savings in chemical costs and downtime losses exceed RMB 1.2 million, with an investment payback period of only 8 months.
This case verifies the technical advantages of Depam's chemical dosing equipment in high-pressure and high-precision scenarios, providing a reference for its promotion in the petroleum refining field.

Reference for Full-text Summary: Technical Upgrade Path for Chemical Dosing Unit Processing Plant
The technological capability of chemical dosing equipment processing plants directly determines the efficiency and stability of chemical agent dosing in industrial production. Depam (Hangzhou) Pump Technology Co., Ltd. has addressed the issues of precision, lifespan, and automation in traditional equipment through high-precision metering pumps, full-material adaptation solutions, and intelligent integrated systems. The successful application of its products in fields such as petroleum refining and chemical engineering demonstrates the value of technological upgrades in reducing operation and maintenance costs and enhancing production efficiency. In the future, with the advancement of Industry 4.0, chemical dosing equipment processing plants will need to further integrate Internet of Things (IoT) and big data technologies to achieve more precise predictive maintenance and process optimization.