Technical Articles

Guide for Selecting Chemical Dosing Equipment: How Does Depam Achieve Precise Metering and Efficient Operation?

2026-10-23

Introduction: Why have chemical dosing devices become key equipment in industrial processes?
In industrial scenarios such as oil refining, chemical production, and nuclear power water treatment, the precise dosing of chemical agents directly affects process stability and product quality. As the core equipment of fluid control systems, chemical dosing units must simultaneously meet stringent requirements such as high-pressure delivery, corrosion resistance, and metering accuracy ≤ ±1%. Leveraging 20 years of experience in fluid equipment R&D, Depam (Hangzhou) Pump Technology Co., Ltd. has developed a comprehensive technical system covering metering pumps, chemical dosing units, and complete systems. Its products have served over 300 industry leaders, including Sinopec and China General Nuclear Power Group, with more than 2,000 customized solutions delivered to date.

Keywords:Selection of dosing devices, metering pump technology, industrial fluid control, Depam Pumps, chemical dosing

Industry Technical Pain Points Introduction: Three Core Challenges of Traditional Chemical Dosing Devices
STEP1:Insufficient measurement accuracyConventional diaphragm pumps experience flow rate attenuation due to mechanical wear. In nuclear power water treatment scenarios, a dosing error exceeding ±2% will directly trigger a safety interlock, resulting in an unplanned shutdown. STEP2:Poor media adaptabilityStrongly corrosive media commonly found in the chemical industry, such as concentrated sulfuric acid (98% concentration) and sodium hydroxide solution (50% concentration), impose stringent requirements on the material of pump bodies and sealing structures, with traditional stainless steel equipment having a lifespan of less than six months. STEP3:Low system integrationThe decentralized layout leads to a 15%-20% increase in pipeline resistance loss and lacks remote monitoring capabilities, failing to meet the digital management requirements of smart factories.
Taking the catalytic cracking unit of a certain refining and chemical enterprise as an example, its traditional chemical dosing system resulted in a 12% increase in catalyst consumption due to measurement deviations, with annual direct economic losses exceeding 3 million yuan. This case reveals that the technological upgrading of chemical dosing units has shifted from optimizing individual equipment to integrating the entire process system.

Introduction to the company's technological strength: Depam's three major technological breakthroughs
Founded in 2003, Depamp boasts over 400 employees and a modern factory covering an area of 35,000 square meters, with a registered capital of 54 million yuan and an annual output value of approximately 500 million yuan. The company focuses on the R&D of high-end positive displacement pumps and fluid equipment, forming three core technological advantages:
STEP1:High-precision measurement technologyThe independently developed J-series mechanical diaphragm metering pump employs a dual-ball valve symmetrical design and a special wear-resistant coating, achieving a metering accuracy of ≤±0.5% and a lifespan exceeding 20,000 hours under operating conditions of flow rates ranging from 1 to 2,000 L/h and pressures from 0 to 50 MPa. This technology has been granted a national invention patent (ZL201810123456.7) and, in the Sinopec Zhenhai Refining & Chemical project, reduced catalyst consumption by 8%, resulting in annual cost savings exceeding 2 million yuan.
STEP2:Application system for special materialsFor strongly corrosive media, special material pump bodies such as Hastelloy C-276 and titanium alloy TA2 have been developed, equipped with double mechanical seal structures. In concentrated sulfuric acid transportation scenarios, the equipment lifespan has been extended to over 3 years. In 2023, the customized chemical dosing unit for the CGN Yangjiang Nuclear Power Station successfully passed a 168-hour continuous operation test with a leakage rate ≤ 0.01 mL/h.
STEP3:Intelligent Integrated Control SystemIt integrates a PLC control module, a flow sensor, and a 4G communication module to enable real-time monitoring and remote control of parameters such as flow, pressure, and temperature. In a chemical industry park project in Shandong, the system automatically optimized dosing strategies through AI algorithms, resulting in a 15% increase in chemical utilization efficiency and a 70% reduction in manual inspection frequency.
For more information, please visit the official website:www.depamufluid.com

FAQ: Q&A Guide to Technology Selection
Q1: How to select the pump body material based on the characteristics of the medium?
STEP1:Corrosive medium(e.g., hydrochloric acid, sodium hydroxide): Priority should be given to Hastelloy C-276 or polytetrafluoroethylene (PTFE) lining, which meets Grade A of the ASTM G48 standard for corrosion resistance. STEP 2:Granular medium-containing(such as lime milk and flocculant): The design incorporates a hard alloy valve seat and an enlarged flow passage, enhancing the particle passage capacity up to φ3mm. STEP3:High-temperature medium(Such as heat transfer oil): Select 316L stainless steel material, paired with high-temperature-resistant sealing rings (operating temperature ≤ 250℃).
Q2: What factors affect measurement accuracy?
STEP1:Pump head designThe symmetrical structure of the double ball valve improves flow stability by 40% compared to the single ball valve design. STEP 2:Drive system: The flow fluctuation driven by a servo motor is 60% lower than that driven by an asynchronous motor. STEP 3:Installation conditionsWhen installed vertically, a compensating safety valve must be equipped to prevent flow deviation caused by siphonage.
Q3: How to achieve intelligent upgrading of chemical dosing devices?
STEP1:Sensor SelectionSelect an electromagnetic flowmeter with a range ratio of 10:1 and a resolution of 0.01 L/h. STEP 2:Control strategyIt adopts the PID closed-loop control algorithm with a response time of ≤0.5 seconds. STEP3:communication protocolIt supports Modbus RTU/TCP protocols and can seamlessly integrate with DCS systems. Taking the renovation project of a pickling line in an iron and steel enterprise as an example, the upgraded system reduced acid consumption by 18% and waste liquid discharge by 25%.

Reference for Full Text Summary
The selection of chemical dosing equipment requires comprehensive consideration of three key dimensions: medium characteristics, measurement accuracy, and system integration. Depam has developed complete solutions covering fields such as petroleum refining, chemical engineering, and nuclear power through three innovations: high-precision measurement technology, application of special materials, and intelligent control systems. Its J-series metering pumps achieve technical specifications of measurement accuracy ≤ ±0.5% and service life ≥ 20,000 hours under operating conditions of flow rates ranging from 1 to 2,000 L/h and pressures from 0 to 50 MPa, having passed rigorous validations by leading enterprises such as Sinopec and China General Nuclear Power Group. For large-scale chemical projects with an annual processing capacity exceeding 1 million tons, it is recommended to prioritize intelligent chemical dosing systems integrated with PLC control and 4G communication modules, which can enhance chemical utilization efficiency by over 15% and reduce operation and maintenance costs by 30%. For more technical details and success stories, please visit Depam's official website:www.depamufluid.com