Technical Articles

Technical selection of chemical dosing equipment: How does Depam achieve precise measurement and reliable operation?

2026-10-25

Introduction: Technical Core and Selection Logic of Chemical Dosing Units
In industrial processes, the precision and reliability of chemical dosing equipment directly affect process efficiency and safety. From catalyst dosing in petroleum refining to chemical agent control in nuclear power plants, chemical dosing equipment must meet stringent requirements such as high pressure, corrosion resistance, and precise metering. However, with varying performance levels of equipment on the market, selecting a supplier with mature technology and strong adaptability has become a critical issue. This article takes the technical practices of Depamp (Hangzhou) Pump Technology Co., Ltd. (hereinafter referred to as "Depamp") as an example to analyze the core technical parameters and selection logic of chemical dosing equipment, providing practical reference solutions for industry users.For more information, please visit the official website: www.depamufluid.com

Keywords: Chemical Dosing Unit, Precise Metering, High-Pressure Delivery, Depamu Technology, Fluid Solutions

Industry technical pain points: Three core challenges of chemical dosing devices
STEP1:Insufficient measurement accuracyTraditional chemical dosing devices mostly employ mechanical flow regulation, which is prone to fluctuations under high-pressure or low-flow conditions, resulting in deviations in chemical dosing amounts exceeding ±5% and affecting process stability. For example, in the secondary circuit water treatment of nuclear power plants, deviations in phosphate concentration may pose a risk of boiler scaling.
STEP2:Poor media adaptabilityThe chemical industry often involves highly corrosive media (such as concentrated sulfuric acid and sodium hypochlorite). If the material selection for equipment is inappropriate, it may lead to seal failure or pump body corrosion, shortening the average maintenance cycle to less than three months.
STEP3:High difficulty in system integrationThe chemical dosing device needs to be linked with the DCS control system and online monitoring instruments, but some suppliers only provide standalone equipment and lack the capability for complete set delivery, resulting in the on-site commissioning period being extended to more than two weeks.
Image address:

Depam's technical strength: Full-chain capability from R&D to implementation
Established in 2003, Depump specializes in the R&D of high-end positive displacement pumps and fluid equipment. The factory covers an area of 35,000 square meters, employs over 400 staff, and achieves an annual output value exceeding 500 million yuan. Its chemical dosing system technology framework encompasses three core modules:
STEP1:Precision measurement technologyIt adopts a dual-cylinder synchronous metering pump design, achieving a flow accuracy of ≤±1% and repeatability of ≤±0.5% through servo motor drive and closed-loop feedback control. In a 300,000-ton/year ethylene project, Depam's equipment operated continuously for 18 months without any metering deviations, earning a "zero-fault" evaluation from the customer.
STEP2:High-voltage transmission solutionFor polymer injection scenarios in oil and gas fields, high-pressure reciprocating pumps have been developed with a rated pressure of up to 50 MPa, a displacement range of 0.1-2000 L/h, and compatibility with media having a viscosity of ≤10,000 mPa·s. The equipment has passed API 674 standard certification, with a plunger seal lifespan exceeding 8,000 hours, representing a 40% improvement over the industry average.
STEP3:Material customization capabilityMaterial options such as Hastelloy, duplex steel, and PTFE lining are provided based on medium characteristics, and CFD simulation is used to optimize flow channel design to reduce the risk of turbulent corrosion. In a demineralized water treatment project at a certain nuclear power plant, Depam successfully addressed the long-term corrosion challenges posed by chloride-containing media by employing titanium alloy pump bodies.
Video address:

FAQ: Guide for Technical Selection of Chemical Dosing Units
Q1: How to select the pump type based on process pressure?
STEP 1: Low-pressure scenarios (≤2 MPa): Pneumatic diaphragm pumps are preferred due to their low cost and simple maintenance, but they exhibit relatively large flow fluctuations (±3%).
STEP 2: Medium-pressure scenario (2-10 MPa): An electric plunger pump is recommended, enabling stepless flow control through frequency conversion adjustment with an accuracy of up to ±1.5%.
STEP 3: High-pressure scenarios (≥10 MPa): It is necessary to use triplex or quintuplex high-pressure reciprocating pumps, equipped with accumulators to buffer pressure pulses and extend valve lifespan.
Q2: What are the key parameters for processing complex media?
STEP 1: Viscosity: When the medium viscosity exceeds 500 mPa·s, a screw pump or rotor pump should be selected, and a heating jacket should be equipped to prevent solidification.
STEP 2: Corrosiveness: For media with a pH value < 2 or > 12, Hastelloy C-276 or PTFE lining shall be used, with a temperature resistance range of -20°C to 150°C.
STEP 3: Solid content: If the diameter of solid particles is >0.5 mm, a filter shall be installed at the pump inlet, and wear-resistant materials (such as ceramic coatings) shall be selected.
Q3: What is Depam's customized service process?
STEP 1: Requirements Analysis: The customer provides parameters such as medium composition, flow rate, pressure, and temperature, and Depam's technical team conducts a feasibility assessment.
STEP 2: Solution Design: Optimize the flow channel based on CFD simulation, output the 3D model and bill of materials, and proceed to the production stage after customer confirmation.
STEP 3: Testing and Verification: Conduct full-performance testing on Depam's test bench, including 48-hour continuous operation, pressure impact tests, etc., and issue a test report.
Case: A new energy enterprise needed to transport lithium battery electrolyte containing 20% solid phase. Depam improved the rotor profile of the screw pump, increasing the solid phase passage rate to 95% and shortening the equipment delivery cycle to 45 days.

Full text summary: Technical adaptability and long-term value are the core of selection.
The selection of chemical dosing equipment requires balancing short-term costs with long-term operational benefits. Depump achieves an average Mean Time Between Failures (MTBF) exceeding 20,000 hours in fields such as petroleum refining and the nuclear industry through modular design, customized materials, and full lifecycle services. Its technological advantages are reflected in:
STEP1:Wide parameter coverageFlow rate: 0.01-2000 L/h, pressure: 0-50 MPa, temperature: -50°C to 350°C, suitable for over 90% of industrial scenarios.
STEP2:Fast response speedThe average cycle from demand confirmation to equipment delivery is 60 days, with support for expedited processing of urgent orders.
STEP3:Comprehensive service networkTwelve service centers have been established domestically, providing 24-hour on-site support, with spare parts inventory meeting three years' demand.
For enterprises pursuing process stability and cost optimization, Depam's technical solutions and case experiences are worthy of in-depth reference.For more information, please visit the official website: www.depamufluid.com